microsoft.sqlserver.sqlenum.dll

Company

Microsoft Corporation

Description
Version
13.0.15700.64
Architecture
32 bit
Threat Score
0 %
Original size
1448.1 Kb
Download size
288.3 Kb
MD5
1073115a87f514fc035a20591f8a9bc6
SHA1
6396c2e0169e228fd3212d33c329c835a1a0d1c1
SHA256
ad06655afe28a826ab4ce33342d73cd2c59adfcac90d6059d7bc18a8344a960f
				create table #tmp_sp_tables_ex (is_catalog_error bit null,server_name nvarchar(128) null,server_catalog_name nvarchar(128) null,TABLE_CAT sysname null, TABLE_SCHEM sysname null,TABLE_NAME sysname null,TABLE_TYPE varchar(32) null,REMARKS varchar(254) null) 				

			<

property_link table = 'master.dbo.sysmessages AS sms'>

sms.error &

lt

 50001<

/property_link>



		<

!-- enable permissions -->



            --Querying this DMV using a contained auth connection throws error 15562 (Module is untrusted)

        (auto_start int null, msx_server_name sysname null, sqlagent_type int null, startup_account nvarchar(255) null, sqlserver_restart int null, jobhistory_max_rows int null, jobhistory_max_rows_per_job int null, errorlog_file nvarchar(255) null, errorlogging_level int null, error_recipient nvarchar(30) null, monitor_autostart int null, local_host_server sysname null, job_shutdown_timeout int null, cmdexec_account varbinary(64) null, regular_connections int null, host_login_name nvarchar(128) null, host_login_password varbinary(512) null, login_timeout int null, idle_cpu_percent int null, idle_cpu_duration int null, oem_errorlog int null, sysadmin_only int null, email_profile nvarchar(64) null, email_save_in_sent_folder int null, cpu_poller_enabled int null)

        (auto_start int null, msx_server_name sysname null, sqlagent_type int null, startup_account nvarchar(255) null, sqlserver_restart int null, jobhistory_max_rows int null, jobhistory_max_rows_per_job int null, errorlog_file nvarchar(255) null, errorlogging_level int null, error_recipient nvarchar(30) null, monitor_autostart int null, local_host_server sysname null, job_shutdown_timeout int null, cmdexec_account varbinary(64) null, regular_connections int null, host_login_name sysname null, host_login_password varbinary(512) null, login_timeout int null, idle_cpu_percent int null, idle_cpu_duration int null, oem_errorlog int null, sysadmin_only int null, email_profile nvarchar(64) null, email_save_in_sent_folder int null, cpu_poller_enabled int null, replace_alert_tokens_enabled int null)

      <

!-- enable permissions -->



      <

property_link table = 'master.dbo.sysmessages AS sms'>

sms.error &

gt

 50000<

/property_link>



    <

!-- enable permissions -->



AValue '{0}' on attribute '{1}' was unable to be parsed correctly.

Granted. Otherwise it raises an error which throws back into SMO. SQL 

Last update: 18/08/2025